TiSO traffic automatic bollards are due in part to the wide range of project applications and the simplicity of installation. This particular TiSO product has been designed and engineered to provide maximum operation durability. The range of TiSO automatic traffic bollards include two types: – blocking segment with built-in hydraulic unit and outside PLC; – blocking segment with an external control box including HPU and PLC. There are a variety of accessories which will ensure that the equipment can operate in severe climate conditions. This includes extreme temperatures below 0 C°. Having no high security features the traffic bollards is the perfect choice for installations at residential premises as well as areas that do not require anti-ramming protection. All the equipment is extensively designed and tested for high intensity operation.
TRAFFIC AUTOMATIC BOLLARDS
Advantages
- Traffic management;
- Traffic calming and safety;
- Security for building and infrastructure;
- Prevent mounting the curb;
- Pedestrian safety;
Specifications
Product downloads
Specification
Technical specs*: | ||||
---|---|---|---|---|
Model | RB349-11 | RB349-12 | RB349-14 | RB349-15 |
Drive | Hydraulic (HPU)/internal | |||
Tube diameter, mm | 220 | 273 | 220 | 273 |
Tube height, mm | 600 | 800 | ||
Foundation case dimensions, mm • LxWxh • AxBxh |
610x755x980 460x610x980 |
660x830x980 515x685x980 |
610x755x1170 460x610x1170 |
660x830x1170 515x685x1170 |
Wall thickness, mm | 4 | 8 | 4 | 8 |
Impact resistance, kJ | 40 | 80 | 45 | 85 |
Breakout resistance, kJ | 160 | 580 | 165 | 585 |
Axle load, t | 15 | |||
Rising time, s | 7,0 | 9,0 | ||
Lowering time, s | 5,5 | 8,0 | ||
Operating temperature**, °С | -40 / +60 | |||
Power supply | 1 phase 230V, 50/60 Hz | |||
Protection level | IP 67 (for bollard) IP 55 (for control box) |
|||
Tube materials | – Brushed stainless steel AISI 304 – Brushed stainless steel AISI 316 – Galvanized and powder coated tube (any RAL up on request) |
|||
* technical data is subject to change without notice ** for temperatures lower than -10 °C use the heating device; for temperatures higher than +40 °C use the cooler device |
Specification
Technical specs*: | ||||
---|---|---|---|---|
Model | RB343-21 | RB343-23 | RB343-24 | RB343-26 |
Drive | Hydraulic (HPU)/internal | |||
Tube diameter, mm | 114 | 170 | 114 | 170 |
Tube height, mm | 600 | 800 | ||
Foundation case dimensions, mm • LxWxh • AxBxh |
610x755x980 460x610x980 |
610x755x1170 460x610x1170 |
||
Wall thickness, mm | 3 | 5 | 3 | 5 |
Impact resistance, kJ | 10 | 35 | 15 | 35 |
Breakout resistance, kJ | 60 | 155 | 65 | 155 |
Axle load, t | 15 | |||
Rising time, s | 7,0 | 9,0 | ||
Lowering time, s | 5,5 | 8,0 | ||
Operating temperature**, °С | -40 / +60 | |||
Power supply | 1 phase 230V, 50/60 Hz | |||
Protection level | IP 67 (for bollard) IP 55 (for control box) |
|||
Tube materials | – Brushed stainless steel AISI 304 – Brushed stainless steel AISI 316 – Galvanized and powder coated tube (any RAL up on request) |
|||
* technical data is subject to change without notice ** for temperatures lower than -10 °C use the heating device; for temperatures higher than +40 °C use the cooler device |